Edit Suite Version 2.01 (MANL-0588-02)
5
3. Lanc_101
If Lanc is used as the source VCR/camcorder and the source randomly
remains in Pause during an auto-assemble, or if a Lanc device is used as
the record VCR and the record VCR randomly remains in Record-Pause,
use this table to fix the problem.
A problem was found with some combinations of Lanc and RS422
devices that caused the Lanc device to remain in pause or record pause
at the start of some scenes.
More specifically, if Lanc was used as the source and RS422 as the
recorder, the source would randomly pause at the preroll point for an
edit and remain there forever. If the reverse setup was used (RS422 as
player/Lanc as recorder), the Lanc VCR would be in record-pause at the
end of a scene but never leave record pause to record the following
scene.
Pana_101
This table has the same changes that were made for Lanc_101. We know
of no combination of VCRs that require this table. However, if you have
symptoms similar to those described for table Lanc_101, try using this
table to fix the problem.
4. RS232_111, 113, 114 , 115
These tables are for RS-232 VCRs when used as source (rather than
record) VCRs; they should be used only if there are problems with the
corresponding "base" tables during auto-record.
USE:
IF THIS TABLE FAILS:
RS232_111
001 (most Sony RS232 VCRs)
RS232_113
003 (most Panasonic RS232 VCRs)
RS232_114
004 (most JVC RS232)
RS232_115
005 (Sony UVW-1400 RS232)
The problem these fix is that, during auto-assemble, the RS232 play
VCR searched to the first preroll point, then paused forever. Tables 111,
113, 114 and 115 fix this problem by eliminating a time code check
during auto-record.
5. RS422_009
This table enhances insert editing with RS422 VCRs. It was available
previously via the NEWVCR function, but is now a permanent part of
the software.
6. RS422_111, 119
These tables are similar to RS232 tables 111-115. There are no VCRs
we know of that require this fix. However, if you encounter a problem
similar to the one described the RS232_111 ... 115, try using these
tables to fix the problem. Use table 422_111 instead of 422_001, or use
422_119 instead of 422_009.