17 Invalid primary tile
A Source (SRC) Event with no duration was encountered during a
preview or auto-record.
Enter a duration for the Source Event.
18 No VITC found
Edit Suite attempted to read VITC time code but was unable to do so.
If the TCSRC parameter is set to INT (internal), ensure that the VCR/
camcorder is set to send VITC instead of LTC, RCTC or counter.
If the TCSRC parameter is set to EXT, ensure that a video cable is
attached from the VCR's video out to the correct Time Code In port
on Edit Suite.
Ensure that there is VITC on your tape. If your VCR can show VITC
on its counter, use that to do your verification. If you have a monitor
with a vertical hold, you can adjust the hold to see the VITC (a series
of short vertical lines) at the top of the video.
If the TCSRC parameter is set to EXT, check the STABLE Advanced
parameter. If it is not set to 45, change it to 45. If it is already 45,
increase its value to 60 and try again. If you increase STABLE, also
increase the PLY (play) parameter by two (2) seconds and the REW
(rewind) parameter by four (4) seconds.
19 No LTC found
Edit Suite attempted to read LTC time code but was unable to do so,
or TCSRC=EXT and TC=NONE or RCTC.
If TC=NONE or RCTC, the TCSRC parameter must be set to INT
(internal).
If TC=LTC and TCSRC=INT (internal), ensure that the VCR/
camcorder is set to send LTC instead of VITC, RCTC or the Real
Time Counter.
If TC=LTC and TCSRC=EXT, ensure that an audio cable is attached
Содержание AB-1 Edit Suite