dPMR Signal Rx Meter Remote Commands
4 - 20
4.9.4
Symbol Clock Error - Lower Limit Value
:LIMits:SCE:CH1:LOWer:VALue
:LIMits:SCE:CH1:LOWer:VALue?
4.9.5
Symbol Clock Error - Measurement Query
:METERs:SCE:CH1:STATus?
4.9.6
Symbol Clock Error - Peak Measurement Reset
:METERs:SCE:CH1:CLEAR:PEAK
4.9.7
Symbol Clock Error - Units
:METERs:SCE:UNIts
:METERs:SCE:UNIts?
Description:
Set command defines Lower Limit Value for Symbol Clock Error measurement.
Query command returns parameter setting.
Range:
0.0 to +1000.0 mHz
Units:
mHz
Default Value:
0.0 mHz
Set/Query Format:
NRf | NR2
Example:
:LIMits:SCE:CH1:LOWer:VALue -500mHz
Sets Lower Limit Value for Symbol Clock Error measurement to -500.0 mHz.
Query Response:
:LIMits:SCE:CH1:LOWer:VALue?
-500.00
Description:
Command returns Symbol Clock Error measurement data.
Query Data:
<statusbyte>,<failbyte>,<precision>,<percentage>,<avg>,<max>,<min>,<units>
Refer to Chapter 1 for UUT Measurement Meter return data.
Query Response:
:METERs:SCE:CH1:STATus?
0,0,3 100.00, -2.487, -0.346, -6.642,18
Description:
Command clears and resets Peak Symbol Clock Error measurement.
Parameter/Query:
none
Description:
Set command defines the unit of measurement for Symbol Clock Error
measurement.
Query command returns parameter setting.
Parameter:
Hz | PPM
Default Value:
Hz
Set/Query Format:
CPD | CRD
Example:
:METERs:SCE:UNIts PPM
Displays Symbol Clock Error measurement in PPM.
Query Response:
:METERs:SCE:UNIts?
PPM
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...