Modulation Accuracy and Power Remote Commands
6 - 3
6.3
DISTRIBUTION GRAPH
6.3.1
Distribution - Persistence
:DISTribution:PERSistence
:DISTribution:PERSistence?
6.3.2
Distribution - Trace Enable
:DISTribution:TRACe:ENABle
:DISTribution:TRACe:ENABle?
Description:
Set command sets Persistence on Distribution graph.
Query command returns parameter setting.
Range:
1 to 10
Default Value:
1
Set/Query Format:
NR1
Example:
:DISTribution:PERSistence 5
Sets Distribution Graph Persistence to 5.
Query Response:
:DISTribution:PERSistence?
5
Description:
Set command Enables/Disables Distribution trace.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:DISTribution:TRACe:ENABle ON
Enables Distribution trace.
Query Response:
:DISTribution:TRACe:ENABle?
1
Trace must be enabled (ON) to return valid data.
N O T E