Analyzer/Receiver Remote Commands
3 - 14
3.7
MODULATION ANALYZER - TONE DECODING
3.7.1
Modulation Analyzers - Clear Decode Log
:MOD:ANALyzer:DECODE:LOGS:CLEAR
3.7.2
Modulation Analyzers - DCS Decode Value
:FETCh:MOD:ANALyzer:DECODE:DCS:VALue?
3.7.3
Modulation Analyzers - Decode Protocol
:MOD:ANALyzer:DECODE:PROTocol
:MOD:ANALyzer:DECODE:PROTocol?
3.7.4
Modulation Analyzers - DTMF Decode Value
:FETCh:MOD:ANALyzer:DECODE:DTMF:VALue?
Description:
Command clears all modulation data logs for Tone Remote, Tone Sequential
and Two Tone Sequential signal types.
Parameter/Query:
none
Description:
Command returns decode value of received signal.
Query Format:
ascii
Query Response:
:FETCh:MOD:ANALyzer:DECODE:DCS:VALue?
047
Description:
Set command selects Protocol to be decoded by the Modulation Analyzer.
Query command returns parameter setting.
Parameter:
ZVEI1 | ZVEI2 | ZVEI3 | PZVEI | DZVEI | PDZVEI | CCIR1 | CCIR2 | PCCIR |
EEA | EUROSIG | NATEL | EIA | MODAT
Default Value:
ZVEI1
Set/Query Format:
CPD | CRD
Example:
:MOD:ANALyzer:DECODE:PROTocol PZVEI
Sets Modulation Analyzer to decode PZVEI Protocol.
Query Response:
:MOD:ANALyzer:DECODE:PROTocol?
PZVEI
Description:
Command returns decode value of received signal.
Query Format:
ascii
Query Response:
:FETCh:MOD:ANALyzer:DECODE:DTMF:VALue?
047
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...