Audio/Demod Signal Rx Meter Remote Commands
5 - 3
5.3.3
AF Measurements - Filter Weight
:CONFigure:AF:MFILter
:CONFigure:AF:MFILter?
5.3.4
AF Measurements - Impedance
:CONFigure:AF:ANALyzer:SOURce:LOAD
:CONFigure:AF:ANALyzer:SOURce:LOAD?
Description:
Set command defines the weight of psoph filter for AF Analyzer when Psoph
filter is selected.
Query command returns parameter setting.
Parameter:
CMESs | CCITt
Default Value:
CMES
Set/Query Format:
CPD | CRD
Example:
:CONFigure:AF:MFILter CCITt
Selects CCITT Psoph Filter for AF measurement.
Query Response:
:CONFigure:AF:MFILter?
CCIT
AF Filter type must be defined as Psoph (:AF:ANALyzer:MFILter PSOPH) for
this command to be valid.
Description:
Set command defines the Impedance of selected Audio Frequency (Receiver)
source.
Query command returns parameter setting.
Parameter:
UNBHI | UNB600
Default Value:
Audio Source defined
Set/Query Format:
CPD | CRD
Example:
:CONFigure:AF:ANALyzer:SOURce:LOAD UNBHI
Sets Impedance of selected Audio Frequency (Receiver) Source to Unbalanced
Hi-Z.
Query Response:
:CONFigure:AF:ANALyzer:SOURce:LOAD?
UNBHI
Command not valid when AF Analyzer Source is set to Balanced
(:CONFigure:AF:ANALyzer:SOURce is set to BAL).
N O T E
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...