5 - 1
Chapter 5 - Audio/Demod Signal
Rx Meter Remote Commands
5.1
INTRODUCTION
This chapter describes the Remote Commands used for configuring and obtaining
Audio/Demod signal measurement data. Remote Commands are listed alphabetically by
meter name.
5.2
ACQUIRE SIGNAL
5.2.1
Reset Signal Acquisition
:RECeive:RESET:ACQuisition
5.3
AUDIO MEASUREMENT CONFIGURATION
5.3.1
AF Measurements - Audio Source
:CONFigure:AF:ANALyzer:SOURce
:CONFigure:AF:ANALyzer:SOURce?
Description:
Command resets signal acquisition
Parameter/Query:
none
Description:
Set command defines the Source for Audio Frequency Analyzer (Receiver) and
Site Sensitivity Search (Option).
Query command returns parameter setting.
Parameter:
AUD1 | AUD2 | BAL | MIC
Default Value:
AUD1
Set/Query Format:
CPD | CRD
Example:
:CONFigure:AF:ANALyzer:SOURce MIC
Selects Microphone as the Audio Frequency Analyzer (Receiver) Source.
Query Response:
:CONFigure:AF:ANALyzer:SOURce?
MIC
Test Set does not process any commands following this one until this command
is completed.