Generator/Transmit Channel Remote Commands
2 - 27
2.7.23
Modulation Generators - Two Tone Sequential FM Deviation
:MOD:GENerator:TTS:DEViation
:MOD:GENerator:TTS:DEViation?
2.7.24
Modulation Generators - Two Tone Sequential Duration
:MOD:GENerator:TTS:nTONE:DURation
:MOD:GENerator:TTS:nTONE:DURation?
Description:
Set command defines the Tone Deviation for Modulation Generator.
Query command returns parameter setting.
Range:
414.0 Hz to 150.0 kHz
Units:
Hz | kHz
Default Value:
2.5 kHz
Set/Query Format:
NRf | NR2 (Hz)
Example:
:MOD:GENerator:TTS:DEViation 4kHz
Sets Mod Generator Deviation to 4.0 kHz
Query Response:
:MOD:GENerator:TTS:DEViation?
4000.0
Description:
Set command defines length of single Tone.
Query command returns parameter setting.
Range:
100 ms to 10 s
Units:
ms | s
Default:
Tone A: 1.0 s
Tone B: 3.0 s
Set/Query Format:
NRf | NR1 (ms)
Example:
:MOD:GENerator:TTS:ATONE:DURation 5s
Sets length of single Tone A burst to 5 seconds.
Query Response:
:MOD:GENerator:TTS:ATONE:DURation?
5000
nTone = A or B (Tone A or B)
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...