Audio/Demod Signal Rx Meter Remote Commands
5 - 53
5.19.8
RF Error - Units
:CONFigure:RF:ANALyzer:RFERRor:UNIts
:CONFigure:RF:ANALyzer:RFERRor:UNIts?
5.19.9
RF Error - Upper Limit Enable
:LIMits:RF:RFERRor:UPPer:ENABle
:LIMits:RF:RFERRor:UPPer:ENABle?
5.19.10
RF Error - Upper Limit Value
:LIMits:RF:RFERRor:UPPer:VALue
:LIMits:RF:RFERRor:UPPer:VALue?
Description:
Set command defines the unit of measurement for RF Error measurement.
Query command returns parameter setting.
Parameter:
Hz | PPM
Default Value:
Hz
Set/Query Format:
CPD | CRD
Example:
:CONFigure:RF:ANALyzer:RFERRor:UNIts PPM
Displays RF Error measurement in PPM.
Query Response:
:CONFigure:RF:ANALyzer:RFERRor:UNIts?
PPM
Description:
Set command Enables/Disables Upper Limit for RF Error measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:RF:RFERRor:UPPer:ENABle ON
Enables Upper Limit for RF Error measurement.
Query Response:
:LIMits:RF:RFERRor:UPPer:ENABle?
1
Description:
Set command defines the Upper Limit Value for RF Error measurement.
Query command returns the Upper Limit Value defined for RF Error
measurement.
Range:
Hz: -5000000.0 to +5000000.0
PPM: 0 to 1000
Default Value:
0.0 Hz
Set/Query Format:
NRf | NR2
Example:
:LIMits:RF:RFERRor:UPPer:VALue 1000Hz
Sets Upper Limit Value for RF Error measurements to 1000.0 Hz.
Query Response:
:LIMits:RF:RFERRor:UPPer:VALue?
1000
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...