2 - 1
Chapter 2 - Generator/Transmit Channel
Remote Commands
2.1
INTRODUCTION
This chapter describes the Remote Commands for configuring dPMR Generator and
Transmit Channel Parameters. Commands are listed alphabetically under headings.
2.2
AF GENERATOR CONFIGURATION
2.2.1
AF Generators - Enable
:AF:GENerator:SOURceN:ENABle
:AF:GENerator:SOURceN:ENABle?
2.2.2
AF Generators - Frequency
:AF:GENerator:SOURceN:FREQuency
:AF:GENerator:SOURceN:FREQuency?
Description:
Set command Enables/Disables the specified AF Generator.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:AF:GENerator:SOURce2:ENABle ON
Enables AF Generator 2.
Query Response:
:AF:GENerator:SOURce2:ENABle?
1
SourceN = 1, 2 or 3 (AF Generator 1, 2 or 3)
Description:
Set command defines the frequency for the specified AF Generator.
Query command returns parameter setting.
Range:
1.0 Hz to 40.0 kHz
Units:
Hz | kHz
Default Value:
AF 1: 1.0 kHz
AF 2: 300.0 Hz
AF 3: 3.4 kHz
Set/Query Format:
NRf | NR2 (Hz)
Example:
:AF:GENerator:SOURce3:FREQuency 15kHz
Sets AF Generator 3 Frequency to 15.0 kHz.
Query Response:
:AF:GENerator:SOURce3:FREQuency?
15000.0
SourceN = 1, 2 or 3 (AF Generator 1, 2 or 3)
N O T E
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...