Audio/Demod Signal Rx Meter Remote Commands
5 - 52
5.19.4
RF Error - Lower Limit Enable
:LIMits:RF:RFERRor:LOWer:ENABle
:LIMits:RF:RFERRor:LOWer:ENABle?
5.19.5
RF Error - Lower Limit Value
:LIMits:RF:RFERRor:LOWer:VALue
:LIMits:RF:RFERRor:LOWer:VALue?
5.19.6
RF Error - Measurement Query
:FETCh:RF:ANALyzer:RFERRor?
5.19.7
RF Error - Peak Measurement Reset
:RF:ANALyzer:RFERRor:CLEAR:PEAK
Description:
Set command Enables/Disables Lower Limit for RF Error measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:RF:RFERRor:LOWer:ENABle ON
Enables Lower Limit for RF Error measurement.
Query Response:
:LIMits:RF:RFERRor:LOWer:ENABle?
1
Description:
Set command defines the Lower Limit Value for RF Error measurement.
Query command returns parameter setting.
Range:
-5000000.0 to +5000000.0 Hz
PPM: 0 to 1000
Units:
Hz | PPM
Default Value:
0.0 Hz
Set/Query Format:
NRf | NR2 (Hz)
Command
Example:
:LIMits:RF:RFERRor:LOWer:VALue 1000Hz
Sets Lower Limit Value for RF Error measurement to 1000.0 Hz.
Query Response:
:LIMits:RF:RFERRor:LOWer:VALue?
1000
Description:
Command returns RF Error measurement data.
Query Data:
<statusbyte>,<failbyte>,<avgcount>,<avg(dB)>,<max(dB)>
Refer to Chapter 1 for UUT Measurement Meter Return Data.
Query Response:
:FETCh:RF:ANALyzer:RFERRor?
0,0,1,874.77,2437.64
Description:
Command clears and resets Peak RF Error measurement.
Parameter/Query:
none
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...