Audio/Demod Signal Rx Meter Remote Commands
5 - 44
5.16.9
Mod Hum & Noise - Reference Value
:CONFigure:MOD:ANALyzer:HN:REFerence:VALue
:CONFigure:MOD:ANALyzer:HN:REFerence:VALue?
5.16.10
Mod Hum & Noise - Upper Limit Enable
:LIMits:MOD:HN:UPPer:ENABle
:LIMits:MOD:HN:UPPer:ENABle?
5.16.11
Mod Hum & Noise - Upper Limit Value
:LIMits:MOD:HN:UPPer:VALue
:LIMits:MOD:HN:UPPer:VALue?
Description:
Set command defines the reference for Modulation Analyzer Hum and Noise
measurement.
Query command returns parameter setting.
Range:
-100.0 to +100.0 dB
Units:
dB
Default Value:
12.0 dB
Set/Query Format:
NRf | NR2
Example:
:CONFigure:MOD:ANALyzer:HN:REFerence:VALue 1dB
Sets Hum & Noise Reference value to 1.0 dB.
Query Response:
:CONFigure:MOD:ANALyzer:HN:REFerence:VALue?
1
Description:
Set command Enables/Disables Upper Limit for Mod Hum & Noise
measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:MOD:HN:UPPer:ENABle ON
Enables Upper Limit for Mod Hum & Noise measurement.
Query Response:
:LIMits:MOD:HN:UPPer:ENABle?
1
Description:
Set command defines Upper Limit Value for Hum and Noise measurement.
Query command returns parameter setting.
Range:
-100.0 to +100.0 dBr
Units:
dBr
Default Value:
10.0 dBr
Set/Query Format:
NRf | NR1
Example:
:LIMits:MOD:HN:UPPer:VALue 75dBr
Sets Upper Limit Value for Mod Hum & Noise measurement to 75.0 dBr.
Query Response:
:LIMits:MOD:HN:UPPer:VALue?
75
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...