Audio/Demod Signal Rx Meter Remote Commands
5 - 23
5.10
AF SNR MEASUREMENTS
5.10.1
AF SNR - Averages
:CONFigure:AF:ANALyzer:SNR:AVERage
:CONFigure:AF:ANALyzer:SNR:AVERage?
5.10.2
AF SNR - Average Measurement Reset
:AF:ANALyzer:SNR:CLEAR:AVG
5.10.3
AF SNR - Lower Limit Enable
:LIMits:AF:SNR:LOWer:ENABle
:LIMits:AF:SNR:LOWer:ENABle?
Description:
Set command defines the number of readings taken to calculate Average AF
SNR measurement.
Query command returns parameter setting.
Range:
1 to 250
Default Value:
1
Set/Query Format:
NR1
Example:
:CONFigure:AF:ANALyzer:SNR:AVERage 75
Sets number of readings taken to calculate Average AF SNR measurement to
75.
Query Response:
:CONFigure:AF:ANALyzer:SNR:AVERage?
75
AF Analyzer Noise measurement type must be defined as Signal to Noise Ratio
(:AF:ANALyzer:NTYPe SN) and SNR measurement defined as Normal
(:CONFigure:AF:ANALyzer:SNR:MODE 1) to obtain valid SNR measurement.
Description:
Command clears and resets Average AF Signal to Noise Ratio measurement.
Parameter/Query:
none
Description:
Set command Enables/Disables Lower Limit for AF Signal to Noise Ratio
measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:AF:SNR:LOWer:ENABle ON
Enables Lower Limit for AF SNR measurement.
Query Response:
:LIMits:AF:SNR:LOWer:ENABle?
1
AF Analyzer Noise measurement type must be defined as Signal to Noise Ratio
(:AF:ANALyzer:NTYPe SN) and SNR measurement defined as Normal
(:CONFigure:AF:ANALyzer:SNR:MODE 1) to obtain valid SNR measurement.
N O T E
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...