Generator/Transmit Channel Remote Commands
2 - 23
2.7.11
Modulation Generators - Tone Remote Functional Level
:MOD:GEN:TONE:REMote:FUNCtion:LEVel
:MOD:GEN:TONE:REMote:FUNCtion:LEVel?
2.7.12
Modulation Generators - Tone Remote Guard Duration
:MOD:GEN:TONE:REMote:GUARD:DURation
:MOD:GEN:TONE:REMote:GUARD:DURation?
2.7.13
Modulation Generators - Tone Remote Guard Frequency
:MOD:GEN:TONE:REMote:GUARD:FREQuency
:MOD:GEN:TONE:REMote:GUARD:FREQuency?
Description:
Set command defines the Tone Level.
Query command returns parameter setting.
Range:
-20.0 to +20.0 dB
Units:
dB
Default Value:
0.0 dB
Set/Query Format:
NRf | NR2
Example:
:MOD:GEN:TONE:REMote:FUNCtion:LEVel 5dB
Sets the Tone Level to 5.0 dB.
Query Response:
:MOD:GEN:TONE:REMote:FUNCtion:LEVel?
5.0
Description:
Set command defines length of single Tone Remote burst.
Query command returns parameter setting.
Range:
1 to 6,000,000 ms
Units:
ms | s | ks
Default:
120 ms
Set/Query Format:
NRf | NR1 (ms)
Example:
:MOD:GEN:TONE:REMote:GUARD:DURation 50ms
Sets length of single Tone Remote burst to 50 milliseconds.
Query Response:
:MOD:GEN:TONE:REMote:GUARD:DURation?
50
Description:
Set command defines Tone Frequency.
Query command returns parameter setting.
Range:
1.0 Hz to 2.999 kHz
Units:
Hz | kHz
Default Value:
2.175 kHz
Set/Query Format:
NRf | NR2 (Hz)
Example:
:MOD:GEN:TONE:REMote:GUARD:FREQuency 15Hz
Sets Tone Frequency to 15.0 Hz.
Query Response:
:MOD:GEN:TONE:REMote:GUARD:FREQuency?
15.0
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...