Audio/Demod Signal Rx Meter Remote Commands
5 - 50
5.18.7
Mod SNR - Peak Measurement Reset
:MOD:ANALyzer:SNR:CLEAR:PEAK
5.18.8
Mod SNR - Upper Limit Enable
:LIMits:MOD:SNR:UPPer:ENABle
:LIMits:MOD:SNR:UPPer:ENABle?
5.18.9
Mod SNR - Upper Limit Value
:LIMits:MOD:SNR:UPPer:VALue
:LIMits:MOD:SNR:UPPer:VALue?
Description:
Command clears and resets Peak Mod SNR measurement.
Parameter/Query:
none
Description:
Set command Enables/Disables Upper Limit for Mod SNR measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:MOD:SNR:UPPer:ENABle ON
Enables Upper Limit for Mod SNR measurement.
Query Response:
:LIMits:MOD:SNR:UPPer:ENABle?
1
Description:
Set command defines the Upper Limit Value for Mod SNR measurement.
Query command returns parameter setting.
Range:
-100.0 to +100.0 dBr
Units:
dBr
Default Value:
0.0 dBr
Set/Query Format:
NRf | NR2
Example:
:LIMits:MOD:SNR:UPPer:VALue 50dBr
Sets Upper Limit Value for Mod SNR measurement to 50.0 dBr.
Query Response:
:LIMits:MOD:SNR:UPPer:VALue?
50
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...