Audio/Demod Signal Rx Meter Remote Commands
5 - 51
5.19
RF ERROR MEASUREMENTS
5.19.1
RF Error - Averages
:CONFigure:RF:ANALyzer:RFERRor:AVERage
:CONFigure:RF:ANALyzer:RFERRor:AVERage?
5.19.2
RF Error - Average Measurement Reset
:RF:ANALyzer:RFERRor:CLEAR:AVG
5.19.3
RF Error - Frequency Resolution Value
:CONFigure:RF:ANALyzer:RFERRor:FRESolution
:CONFigure:RF:ANALyzer:RFERRor:FRESolution?
Description:
Set command defines number of readings taken to calculate Average RF Error
measurement.
Query command returns parameter setting.
Range:
1 to 250
Default Value:
1
Set/Query Format:
NR1
Example:
:CONFigure:RF:ANALyzer:RFERRor:AVERage 75
Sets number of readings taken to calculate Average RF Error measurement to
75.
Query Response:
:CONFigure:RF:ANALyzer:RFERRor:AVERage?
75
Description:
Command clears and resets Average RF Error measurement.
Parameter/Query:
none
Description:
Set command defines RF Error Frequency Resolution.
Query command returns parameter setting.
Parameter:
1 | 10
Units:
Hz
Default Value:
1 Hz
Set/Query Format:
NRf | NR1
Example:
:CONFigure:RF:ANALyzer:RFERRor:FRESolution 10
Sets RF Error Frequency Resolution to 10 Hz.
Query Response:
:CONFigure:RF:ANALyzer:RFERRor:FRESolution?
10
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...