dPMR Signal Rx Meter Remote Commands
4 - 3
4.3.7
Bit Error Rate - Receive Pattern
:METERs:BER:PATTern
:METERs:BER:PATTern?
4.3.8
Bit Error Rate - Upper Limit Enable
:LIMits:BER:CH1:UPPer:ENABle
:LIMits:BER:CH1:UPPer:ENABle?
4.3.9
Bit Error Rate - Upper Limit Value
:LIMits:BER:CH1:UPPer:VALue
:LIMits:BER:CH1:UPPer:VALue?
Description:
Set command defines Receive Pattern for Bit Error Rate measurement.
Query command returns parameter setting.
Parameter:
STD1031 | STDCAL | STDCAL1 | STDCAL5 | FSWPN9 | STDSILENCE |
STD511 | FRAMESYNC
Default Value:
STD511
Set/Query Format:
CPD | CRD
Example:
:METERs:BER:PATTern STD1031
Sets Receive Pattern for Bit Error Rate measurement to Standard 1031 Pattern.
Query Response:
:METERs:BER:PATTern?
STD1031
Description:
Set command Enables/Disables Upper Limit for Bit Error Rate measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:BER:CH1:UPPer:ENABle ON
Enables Upper Limit for Bit Error Rate measurement.
Query Response:
:LIMits:BER:CH1:UPPer:ENABle?
1
Description:
Set command defines Upper Limit Value for Bit Error Rate measurement.
Query command returns parameter setting.
Range:
0.0 to 100.0%
Units:
% (percent)
Default Value:
0.0%
Set/Query Format:
NRf | NR2
Example:
:LIMits:BER:CH1:UPPer:VALue 5
Sets Upper Limit Value for Bit Error Rate measurements to 5%.
Query Response:
:LIMits:BER:CH1:UPPer:VALue?
5.0000000000
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...