dPMR Signal Rx Meter Remote Commands
4 - 13
4.7
INBAND POWER
4.7.1
Inband Power - Averages
:METERs:POWer:CHn:INBand:AVERaging
:METERs:POWer:CHn:INBand:AVERaging?
4.7.2
Inband Power - Average Measurement Reset
:METERs:POWer:CHn:INBand:CLEAR:AVG
4.7.3
Inband Power - Lower Limit Enable
:LIMits:POWer:CHn:INBand:LOWer:ENABle
:LIMits:POWer:CHn:INBand:LOWer:ENABle?
Description:
Set command defines number of readings taken to calculate Average Inband
Power measurement.
Query command returns parameter setting.
Range:
1 to 250
Default Value:
1
Set/Query Format:
NR1
Example:
:METERs:POWer:CH1:INBand:AVERaging 100
Sets the number of readings taken to calculate Channel 1 Inband Power
measurements to 100.
Query Response:
:METERs:POWer:CH1:INBand:AVERaging?
100
CHn = 1 or 2 (Channel 1 or 2). Channel 2 is option enabled.
Description:
Command clears and resets Average Inband Power measurement.
Parameter/Query:
none
CHn = 1 or 2 (Channel 1 or 2). Channel 2 is option enabled.
Description:
Set command Enables/Disables Lower Limit for Inband Power measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:POWer:CH1:INBand:LOWer:ENABle ON
Enables Lower Limit for Channel 1 Inband Power measurement.
Query Response:
:LIMits:POWer:CH1:INBand:LOWer:ENABle?
1
CHn = 1 or 2 (Channel 1 or 2). Channel 2 is option enabled.
N O T E
N O T E
N O T E
Содержание 3900 Series
Страница 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Страница 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...