P
ROGRAMMING
S
YSTEM
F
EATURES
> S
PECIFYING
U
SER
N
AMES
FOR
X
101
AND
X
108
DX-80 Programming Manual
- 68 -
4.4.2 PROGRAMMING USING PC-DBA
1. Select
Programming
from the PC-DBA menu and press
Enter
. The system displays the Database Program-
ming menu.
2. Use the arrow keys to highlight
System Resource
and press
Enter
. The system displays the System
Resource menu.
3. Highlight
User Password
and press
Enter
. The system displays the System Resource — User Password
menu.
4. First, program the user password length. Use the arrow keys to highlight
Length
, then press
Enter
. Key in
the password length (from 4 to 8) you want to use, then press
Enter
. The default length is 4.
5. Next, program the passwords you want to use for extensions 101, 102, and 108. Use the down arrow key to
highlight the
Password
field for directory number 101 and press
Enter
.
6. Enter the password you want to use. Valid passwords use any alphanumeric characters, up to the extension
length you just programmed (if you set the length to 5, valid passwords have five alphanumeric characters,
etc.). The default is for extension 101 is 9999; the default password for all other extensions is 0000.
7. In the same manner, program the passwords for extensions 102 and 108.
8. When you are done, press
Esc
to return to the Database Programming screen. The system prompts: “Exit
This Feature?”; press
Y
for yes.
9. The system prompts “Save Current Setting?” Press
Y
to save your changes.
10. The system then prompts “File Exists, Override?” Press
Y
to continue with the save operation.
11. Press
Esc
to return to the Database Programming menu.
12. When you have finished all programming changes, perform a Send operation to copy your new database to
the DX-80 switch system memory. For more details, see Section 2.1.4.4,
4.5 Specifying User Names for x101 and x108
You can assign an alphanumeric, seven-character title to each extension in the system. The system displays this
title on the digital speakerphone in place of the standard “EXT” message.
Содержание Comdial DX-80
Страница 1: ...Programming Manual Technical Manual Volume II GCA60 001 RB1105 ...
Страница 4: ... iv This Page Intentionally Left Blank ...
Страница 18: ...This page intentionally left blank ...
Страница 28: ...OVERVIEW PROGRAMMING A NEW SYSTEM DX 80 Programming Manual 28 This Page Intentionally Left Blank ...
Страница 58: ...GETTING STARTED SHORTCUTS TO HELP YOU WORK FASTER DX 80 Programming Manual 58 ...
Страница 284: ...PROGRAMMING EXTENSIONS CONFIGURING SINGLE LINE TELEPHONES ANALOG DEVICE SUPPORT DX 80 Program 284 ...
Страница 290: ...PROGRAMMING FEATURE BUTTONS FEATURE KEY RESET DX 80 Programming Manual 290 This Page Intentionally Left Blank ...
Страница 291: ... 291 A WORKSHEETS Worksheets DX 80 Programming Manual ...
Страница 292: ...APPENDIX A DX 80 Programming Manual 292 ...
Страница 293: ... 293 DX 80 Programming Manual APPENDIX A ...
Страница 294: ...APPENDIX A DX 80 Programming Manual 294 ...
Страница 295: ... 295 DX 80 Programming Manual APPENDIX A ...
Страница 296: ...APPENDIX A DX 80 Programming Manual 296 ...
Страница 297: ... 297 DX 80 Programming Manual APPENDIX A ...
Страница 298: ...APPENDIX A DX 80 Programming Manual 298 ...
Страница 299: ... 299 DX 80 Programming Manual APPENDIX A ...
Страница 300: ...APPENDIX A DX 80 Programming Manual 300 ...
Страница 301: ... 301 DX 80 Programming Manual APPENDIX A ...
Страница 302: ...APPENDIX A DX 80 Programming Manual 302 ...
Страница 303: ... 303 DX 80 Programming Manual APPENDIX A ...
Страница 304: ...APPENDIX A DX 80 Programming Manual 304 ...
Страница 305: ... 305 B BUTTON LABELING Cut along all dotted lines C O M D I A L D X 8 0 DX 80 Programming Manual ...
Страница 308: ...APPENDIX B DX 80 Programming Manual 308 This Page Intentionally Left Blank ...
Страница 321: ... 321 DX 80 Programming Manual INDEX This page intentionally left blank ...