4. Operation
4.1 Caution on Operation
WARNING
This pump is not pressure-proof.
Never run the Vacuum pump on blocking up the exhaust outlet, putting
any device that hampers the gas passage or putting any oil mist trap not
conforming to the ULVAC pump. There is a risk that the pressure inside
the rises up as far as the Pump unit and/or Oil level gauge breaks or the
Motor gets overloaded.
This product is not made as the withstand pressure structure. Ensured
pressure value of the Pump shall be 0.03MPaG (0.3kg/cm
2
G) (Gauge
pressure).
If any valve was put to a pipe after the Exhaust outlet, check and ensure
that it is open.
WARNING
Never fail to flow the coolant during operation, Required coolant
volume
shall be;
VS1501 : 4~6 L/min
VS2401 : 5~7 L/min
This machine adopts the air introduction method to reduce the noise on
achieving the ultimate pressure (called
“
punch noise.
”
) The punch
noise shall be mitigated by breathing in slight air through the slow leak
valve.
Take off the slow leak valve if any trouble was predicted to breathe in
the air. That time the punch noise shall remain as it is.