SK00-4390-DI-002-11
ix
Power Supply wiring <Dismantling>
Be sure to cut off the electricity before starting install or dismantling
operation.
Coolant piping <Dismantling>
Should you remove the Coolant joint immediately after having stopped
the Pump, there is a risk that the coolant remained inside the Pump
comes to a boil and jets out. Keep flowing the Coolant as far as the
Pump temperature cools down.
The Pump is and remains very hot during and while after having stopped
operation. You have a risk of getting burned if a part of the body touched
it.Keep flowing the Coolant as far as the Pump temperature cools down.
Use a flow meter (HWFM: for example Flow sight) applicable to visually
check the Coolant supply source that no water is flowing.
Inlet piping <Dismantling>
Take off the piping following the Install Manual of the system.
The Inlet piping remains very hot wile after having stopped the Pump. Be
sure to take it off after the Pump has sufficiently cooled down.
Make airtight completely the Pump exhaust outlet with a blank flange.
Transfer
You have a risk of giving damage to your back as the load larger than
safety standard shall be required to transfer the product.
VS1501
:
232kg
VS2401
:
271kg
Be sure to use the loading machinery (such as mobile crane) to lift up the
Pump or load it on the pallet and fix it with Jack and run the Pallet truck
for its transfer.
WARNING
WARNING
WARNING
WARNING
Содержание VS1501
Страница 2: ......
Страница 13: ...SK00 4390 DI 002 11 xi Fig 1 Warning Label display position...
Страница 27: ...SK00 4390 DI 002 11 7 Fig 2 VS1501 Dimensional drawing...
Страница 28: ...SK00 4390 DI 002 11 8 Fig 3 VS2401 Dimensional drawing...
Страница 36: ...SK00 4390 DI 002 11 16 Fig 5 Suction Exhaust piping connection diagram...