SK00-4390-DI-002-11
xiii
Table. 1 standard accessories
Part name
Specification
Quantit
y
Remarks
Oil one time portion
ULVOIL R-72
1 set
For the consumed amount,
refer to the specification table.
Instruction manual
English
1 copy
-
0.5.2 Transfer
You have a risk of giving damage to your back as the load larger than
safety standard shall be required to transfer the product.
VS1501
:
232kg
VS2401
:
271kg
Be sure to use the loading machinery (such as mobile crane) to lift up the
Pump or load it on the pallet and fix it with Jack and run the Pallet truck
for its transfer.
0.5.3 Ambient Condition for Storage, Install and Operation
As precise clearances are provided with this machine, be sure to fulfill the following for its
storage, install and operation;
(1) Ambient temperature and humidity for storage : -30°C to 60°C, less than 95%RH
(2) Ambient temperature and humidity for
operation
: 10°C to 40°C, less than 80%RH
(3) Height (for both storage and operation)
: Lower than el. 1,000m.
(4) External vibration (for both storage and
operation)
:
Vibration
acceleration
less
than114dB (0.5G)
(5) Miscellaneous (for both storage and operation) :
a. There shall be no corrosion behavior or explosive gas.
b. There shall be no freeze or dew formation.
c. There shall be no dust.
d. It shall be in house.
e. Another pump shall not be put on the Pump.
The Pump shall not be laid down nor put touching its motor edge face or oil gauge
edge face with the ground.
f. There shall be no direct sun beam.
g. Heat source shall be put away from the Pump.
WARNING
Содержание VS1501
Страница 2: ......
Страница 13: ...SK00 4390 DI 002 11 xi Fig 1 Warning Label display position...
Страница 27: ...SK00 4390 DI 002 11 7 Fig 2 VS1501 Dimensional drawing...
Страница 28: ...SK00 4390 DI 002 11 8 Fig 3 VS2401 Dimensional drawing...
Страница 36: ...SK00 4390 DI 002 11 16 Fig 5 Suction Exhaust piping connection diagram...