“CALIBRATE INTERATION”.
Figure 160 Dialogue box popped out when entering sub-screen “System deviation”
Note: It’s better to perform the system deviation calibration twice continuously.
In case of first installation and initial calibration, select “CALIBRATE AGAIN” (that
is, clear the results of last system deviation calibration during the calibration process).
When the calibration is done, enter the calibration options of “System deviation”
again to select “CALIBRATE INTERATION” (that is, reserve the results of last
system deviation calibration during the calibration process, and perform the
calibration based on the data obtained during last calibration process to further
eliminate the system deviation).
Figure 161 Perform system deviation calibration
As shown in the figure above, perform the system deviation calibration step by step as
instructed in the pop-up box below.