103
/
167
5.5.2
Guide Wheel Calibration
When the calibration zeroing is done, first perform guide wheel calibration. The
purpose of calibration is to obtain the maximum angle value of the left and right
steering of guide wheel and the middle point of the guide wheel during the straight
line driving of farming vehicle.
Touch the guide wheel steering range calibration button
in the calibration screen,
and the sub-screen as shown in the figure below pops out in the screen.
Figure 138 Sub-screen popping out for guide wheel calibration
In this sub-screen,
box contains numerical values to indicate the real-time
angle of guide wheel,
uses a pointer to display the real-time angle of guide
wheel, and
shows the left & right limit and middle point
information of guide wheel obtained during the operation according to relevant
instructions. AG960 measures the guide wheel angle with 360° non-contact sensor,
therefore, the value of guide wheel angle ranges from 0° to 360°.
Calibration of the steering range of guide wheel can be completed by following the
instructions in the sub-screen of guide wheel steering range calibration.