51
/
167
Figure 72 Determine the connection position of L-shaped adapter plate on tractor (left), hang
and tighten hydraulic valve (right)
4.3.1.4
Connect Port P of Power Steering Pump and Port P of
Hydraulic Valve
Disconnect the existing connection at port P of power steering pump (pressure output
port) and connect it to port P of hydraulic valve with transition union and oil pipe. The
existing connection can be disconnected directly from port P of power steering pump
or the other end of oil tube of port P of power steering pump, whichever is convenient
for the installation process.
Figure 73 Disconnect existing connection at port P of power steering pump, mount transition
union, and connect it to port P of hydraulic valve with oil pipe