![TERSUS AG960 Скачать руководство пользователя страница 147](http://html1.mh-extra.com/html/tersus/ag960/ag960_user-manual_1090360147.webp)
146
/
167
Figure 191 Set the operation width with shortcuts
The operation width is calculated as “the actual distance measured from the leftmost
tip of the implement (or where the seed is planted) to the rightmost tip of the
implement (or where the seed is planted) + internal row spacing of the implement”.
The following are some typical examples of calculation of the operation width of
implement.
Figure 192 Operation width calculation of corn planter
Operation width of a corn planter = 350cm (Distance measured from the
leftmost seed planting point to the rightmost seed planting point of farm
tool) + 70cm (Internal row spacing of farm tool) = 420cm