April
2018
Pathfinder DVL Guide
Page 218
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
The
PD6
output does not pad spaces with zeroes. The spaces are left intact. The example below shows a
realistic output from a Pathfinder locked onto the bottom and the values of the System Health Monitor
Data is shown in red.
:SA, -2.31, +1.92, 75.20
:TS,04081111563644,35.0,+21.0, 0.0,1524.0, 0
:WI,-32768,-32768,-32768,-32768,V
:WS,-32768,-32768,-32768,V
:WE,-32768,-32768,-32768,V
:WD, +0.00, +0.00, +0.00, 20.00, 0.00
:BI, +24, -6, -20, -4,A
:BS, -13, +21, -20,A
:BE, +17, +18, -20,A
:BD, -0.02, -0.03, +0.02, 7.13, 0.21
:HM,G,G,0C8E,0B2E,33.214,1.215,27.337<CR><LF>
33.214 Volts, 1.215 amps, 27.337 ohms
Pathfinder Output Data Format (PD13)
The Pathfinder sends this data format only when the
PD13
command is used. The DVL outputs data in the
following line order. The DVL may not sent all data lines. Examples: (1) If BK = zero, the DVL does not
send water-mass data (line items beginning with W); (2) If BK = three, the DVL does not send bottom-
track data (line items beginning with B).