Pathfinder DVL Guide
April
2018
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 107
#BJ – Data Type Output Control
Purpose:
Bottom data types that will be output in the ensemble.
Format:
Format #BJ tc* hrn ***
The BJ commands work with or without the # sign. For example, using BJ or #BJ are both valid
commands.
*: not used; reserved for future use (set to zero).
t: Standard bottom track output (see
Binary Bottom-Track Data Format
c: Commands output (see
Bottom Track Command Output Format
for a definition of this
data type)
h: High resolution bottom and water mass velocity and distance (note that this will cause
distance to be accumulated). See
Bottom Track High Resolution Velocity Format
data type definition)
r: Range (corrected) output. See
n: Precision Navigation Output. See
Navigation Parameters Data Format
for data type
definition.
Range:
0 or 1 for each digit
Default:
#BJ 100 000 000
The default setting for this command is recommended for most applications.
Description:
This command controls the data types that are output in the ensemble.
Include the spaces between the groups of three digits for readability. The command is
accepted with or without spaces.
#BK - Water-Mass Layer Mode
Purpose
Selects the ping frequency of the water-mass layer ping
Format
#BKn
The BK commands work with or without the # sign. For example, using BK or #BK are both
valid commands.
Range
n = 0 to 3
Default
BK0
The default setting for this command is recommended for most applications.
Description
The BK command selects how often the Pathfinder performs a water-mass layer ping
while bottom tracking. The number of water-mass layer pings per ensemble is dependent
on the BP-command (see
BP – Bottom-Track Pings per Ensemble
) and this command
setting. Use the #BL-command to set the location of the water-mass layer (see
).