Pathfinder DVL Guide
April
2018
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 157
ALWAYS OUTPUT
7F7Fh
HEADER
(6 BYTES + [2 x No. OF DATA TYPES])
0000h
FIXED LEADER DATA
(58 BYTES)
0080h
VARIABLE LEADER DATA
(77 BYTES)
WATER PROFILING
DATA
WD command
WP command
0100h
VELOCITY
(2 BYTES + 8 BYTES PER DEPTH CELL)
0200h
CORRELATION MAGNITUDE
(2 BYTES + 4 BYTES PER DEPTH CELL)
0300h
ECHO INTENSITY
(2 BYTES + 4 BYTES PER DEPTH CELL)
0400h
PERCENT GOOD
(2 BYTES + 4 BYTES PER DEPTH CELL)
BP command
#BJ command
0600h
BOTTOM TRACK DATA
(81 BYTES)
5800h
BOTTOM TRACK COMMAND OUTPUT
(43 BYTES)
5803h
BOTTOM TRACK HIGH RESOLUTION VELOCITY
(70 BYTES)
5804h
BOTTOM TRACK RANGE
(41 BYTES)
2013h
NAVIGATION PARAMETERS DATA
(85 BYTES)
#EE command
3000h
ENVIRONMENT COMMAND PARAMETERS OUTPUT
(47 BYTES)
3001h
SENSOR SOURCE FOR DOPPLER PROCESSING
(62 BYTES)
SD command
541Ch
STATUS
(24 BYTES)
541Dh
IMU DATA
(60 BYTES)
541Eh
EULER Data
(34 BYTES)
541Fh
SHIP MOTION
(48 BYTES)
ALWAYS OUTPUT
CHECKSUM
(2 BYTES)
Figure 30.
PD0 Standard Output Data Buffer Format
Some data outputs are in bytes per depth cell. For example, if the WN-command = 30 (default), WD com-
mand = WD 111 110 000 (default), WP command > 0, BP command > 0, the required data buffer storage
space is 951 bytes per ensemble. There are seven data types output for this example: Fixed Leader, Varia-
ble Leader, Velocity, Correlation Magnitude, Echo Intensity, Percent Good, and Bottom Track.
20 BYTES OF HEADER DATA (6 + [2 x 7 Data Types])
58 BYTES OF FIXED LEADER DATA (FIXED)
77 BYTES OF VARIABLE LEADER DATA (FIXED)
242 BYTES OF VELOCITY DATA (2 + 8 x 30)
122 BYTES OF CORRELATION MAGNITUDE DATA (2 + 4 x 30)
122 BYTES OF ECHO INTENSITY (2 + 4 x 30)
122 BYTES OF PERCENT-GOOD DATA (2 + 4 x 30)
122 BYTES OF PROFILE STATUS DATA (2 + 4 x 30)
81 BYTES OF BOTTOM TRACK DATA (FIXED)
2 BYTES OF CHECKSUM DATA (FIXED)
968 BYTES OF DATA PER ENSEMBLE