Pathfinder DVL Guide
April
2018
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 117
CZ – Power Down ADCP
Purpose
Tells the Pathfinder to power down.
Format
CZ
Recommended Setting.
Use as needed.
Description
Sending the CZ command powers down the DVL and draws a minimal amount of current.
Pathfinder processing is interrupted and the DVL goes in the STANDBY mode (RAM is
maintained).
Example
See below
>cz
Powering Down
A Hard Break will re-wake the unit. Note that this only works over serial, not Ethernet.
Only a Hard Break will wake up the DVL from sleep. Using a Software Break will not work.
Expert Control System Commands
This section lists the expert Control System commands. Commands that start with the # sign are consid-
ered “expert” commands.
>#c?
Available Commands:
#CT 0 ---------------------- Turnkey [0 = OFF, 1 = ON]
#C? ------------------------ Display #C-Command Menu