Pathfinder DVL Guide
April
2018
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 165
Table 33:
Fixed Leader Data Format
Hex Digit
Binary
Byte
Field
Description
69-72
35,36
WT Xmit pulse
length
This field, set by the WT-command (
), contains
the length of the transmit pulse. When the Pathfinder receives a
<BREAK> signal, it sets the transmit pulse length as close as possible
to the depth cell length (
). This means the Path-
finder uses a WT command of zero. However, the WT field contains
the actual length of the transmit pulse used.
Scaling: LSD = 1 centimeter; Range = 0 to 65535 cm (2150 feet)
73,74
75,76
37,38
Spare
Spare
77,78
39
#WA / False Tar-
get Threshold
Contains the threshold value used to reject data received from a
false target, usually fish (
WA - False Target Threshold Maximum
Scaling: LSD = 1 count; Range = 0 to 255 counts (255 disables)
79,80
40
Spare
Contains the CX-command setting. Range = 0 to 5
81-84
41,42
LagD / Transmit
lag distance
This field, determined mainly by the setting of the WM-command,
contains the distance between pulse repetitions.
Scaling: LSD = 1 centimeter; Range = 0 to 65535 centimeters
85-100
43-50
Spare
Spare
101-105
51-52
System Band-
width
Contains the system bandwidth setting.
Range = 0 to 1
106-107
53
Spare
Spare
108-109
54
Spare
Spare
110-119
55-58
System Serial
Number
System Serial Number