5-24
Standard
Waveforms
Control
Commands
This group is used to control the standard waveforms and their
respective parameters. There is an array of standard waveforms
that could be used without the need to download waveform
coordinates to the instrument. You can also modify the parameters
for each waveform to a shape suitable for your application.
Factory defaults after *RST are shown in the Default column.
Parameter range and low and high limits are listed, where
applicable.
Table
5-3, Instrument Control Commands Summary
Keyword
Parameter Range
Default
:FUNCtion
:SHAPe
SINusoid
| TRIangle | SQUare | PULSe | RAMP | SINC |
GAUSsian | EXPonential | NOISe | DC
SIN
:SINusoid
:PHASe
0 to 360
0
:TRIangle
:PHASe
0 to 360
0
:SQUare
:DCYCle
0 to 99.99
50
:PULSe
:DELay
0 to 99.999
10
:WIDth
0 to 99.999
10
:TRANsition
[:LEADing]
0 to 99.999
10
:TRAiling
0 to 99.999
10
:RAMP
:DELay
0 to 99.99
0
:TRANsition
[:LEADing]
0 to 99.99
60
:TRAiling
0 to 99.99
30
:SINC
:NCYCle
4 to 100
10
:GAUSsian
:EXPonent
10 to 200
20
:EXPonential
:EXPonent
-100 to 100
1
:DC
[:AMPLitude]
-5 to 5
5
Содержание 5064
Страница 26: ...1 5 Figure 1 2 ArbConnection The Control Panels Figure 1 3 ArbConnection The Wave Composer...
Страница 71: ...2074 User Manual 2 18 This page intentionally left blank...
Страница 145: ...2074 User Manual 3 74 Figure 3 48 Reading the 2074 Internal Temperature...
Страница 207: ...2074 User Manual 4 62 Figure 4 47 Complete Pulse Train Design Figure 4 48 Section 5 of the Pulse Train Design...
Страница 220: ...4 ArbConnection Logging SCPI Commands 4 75 Figure 4 58 Log File Example...
Страница 221: ...2074 User Manual 4 76 This page was intentionally left blank...
Страница 333: ...2074 User Manual 7 2...
Страница 358: ...7 Adjustments and Firmware Update Updating 2074 Firmware 7 27 Figure 7 9 Firmware Update Completed...
Страница 359: ...2074 User Manual 7 28 This page was intentionally left blank...
Страница 360: ...Appendices Appendix Title Page A Specifications A 1 1...
Страница 361: ...2074 User Manual 2...