AutoDyn
Operators Manual
Section 9 - Page 6
CH9 AutoDyn Description of the Config File.fm
Channel 2 - Trq1 (2WD systems)
RWTrq1 (AWD systems)
Channel 2 is used to measure the torque from the differential and the
eddy current power absorber. It senses the voltage from the strain gauge
and converts it into torque for calculations and power measurement. The
default strain gauge calibration coefficient is approximately 1816.9189 lb-
ft
[2463.3786 Nm]
per volt. This coefficient will be changed via calibration.
The channel is set up for zeroing by command and is set for an automatic
filter (allows changes via test profiles). This channel is given parameters
so it may be used as a control channel. Is has values set at -9999
minimum and +9999 maximum.
0.000 4.096 volts
0.000 7442.1 lb-ft
[10090 Nm]
Channel 3 - FWTrq2 (AWD systems only)
For All Wheel Drive (AWD) systems, this channel is used as a measured
sensor input for the front rollset load cell. It is then configured the same as
channel 2, RWTrq1. However, during calibration, the calibration value
must be input as a NEGATIVE number. For this reason, AWD systems
may not be run in reverse direction.
0.000 4.096 volts
0.000 7442.1 lb-ft
[10090 Nm]
Channel 4 - LambVt
Channel 4 is used for auxiliary voltages for expansion. It may be used for
0-5 vdc sensors on -2242 board sensor boxes, or 0-10vdc sensors on
2060-01 board sensor boxes. It is currently defined for use with Lambda
sensor inputs. The channel is set for a coefficient of 1.000 and does not
require calibration. Filtering is set to 5 and no zeroing (zeroing is not
recommended for this channel when using the -2242 board). The
maximum voltage on 2242 boards is 4.096 vdc. The channel may be
zeroed on 2242 boards if a sensor is connected or if the signal source, pin
5, is grounded.
0.000 4.096 volts
0.000 4.096 volts
Channel 5 - OilTvt
Channel 5 is used for auxiliary voltages for expansion. It may be used for
0-5 vdc sensors on -2242 board sensor boxes, 0-10vdc sensors on 2060-
01 board sensor boxes. It is currently defined for use with Oil Dipstick
sensor inputs. The channel is set for a coefficient of 1.000 and does not
require calibration. Filtering is set to 5 and no zeroing (zeroing is not
recommended for this channel when using the -2242 board). The
maximum voltage on 2242 boards is 4.096 vdc. The channel may be
zeroed on 2242 boards if a sensor is connected or if the signal source, pin
5, is grounded. This channel may be used for other voltage type inputs for
systems equipped with a thermocouple module to measure temperatures.
0.000 4.096 volts
0.000 4.096 volts
Содержание AutoDyn
Страница 4: ...AutoDyn Operators Manual Section 1 Page 4 AutoDyn Cover fm...
Страница 5: ...1 General Information...
Страница 10: ...S Y S T E M O V E R V I E W Section 2 Page 1 2 System Overview...
Страница 24: ...P A C K A G I N G A N D H A N D L I N G Section 3 page 1 Packaging and Handling 3...
Страница 29: ...T E S T A R E A R E Q U I R E M E N T S Section 4 page 1 4 Test Area Requirements...
Страница 40: ...I N S T A L L A T I O N Section 5 Page 1 5 Installation...
Страница 55: ...6 System Operation...
Страница 60: ......
Страница 78: ...H A N D H E L D C O N T R O L L E R Section 7 Page 1 7 Handheld Controller...
Страница 104: ...8 Theory Of Testing...
Страница 114: ...Theory Of Testing Volume 2 9 10 04 Section 8 Page 13 Figure 8 1 Frontal Area Coefficient of Drag US...
Страница 115: ...AutoDyn Operators Manual Section 8 Page 14 Theory Of Testing fm Figure 8 2 Frontal Area Coefficient of Drag Metric...
Страница 123: ...9 Description of the Configuration File...
Страница 172: ...20 Service and Calibration...
Страница 178: ...S E R V I C E A N D C A L I B R A T I O N Section 20 page 7 20 2 Maintenance record...
Страница 193: ...A General Testing Information Appendix...
Страница 205: ...B Fundamental Concepts to Obtaining Superior Repeatability Appendix...