Description of the Configuration File
Volume 2, Rev 2 6/28/04
Section 9 - Page 5
9.1
Overview
The Configuration file is used to define the functions of WinDyn and the NGE Data Acquisition
System. The Channel Functions, Control Functions, and the Console Display are all defined in the
Configuration File. Once established, the file is stored on the PC hard disk and downloaded to the
Data Acquisition System memory as required. This file defines the basic elements of WinDyn and
is required for proper operation.
9.2
Channel Definitions
Values in
italic
and / or [between brackets] are for metric configurations. Gaps in the numbering of
are channels that are not defined or are used as a calculated channel.
9.2.1
Measured Channels
Sensor channels input measured data and convert it to a reading. In some cases the reading is a
direct reflection of the input, such volts in to volts out. In other cases the input is convert to a
different value, such as volts in to A/F Ratio out or frequency to RPM. Thermocouple channel
values are determined by the type of thermocouple used.
On the following channel definitions, the first line after the channel description is the input
minimum and maximum values. The second line are the displayed values.
Channel 1 - AirSen
Channel 1 is used to measure the voltage from the ambient air
temperature sensor. The voltage is used by Channel 74 to determine the
air temperature. This channel has a coefficient of 1.000, no auto zero, and
is filtered at 7. Changing the values for this channel is not recommended.
Changing the coefficient will alter the values displayed by channel 74.
This channel typically requires no calibration.
0.000 1.000 volts
0.000 1.000 volts
Содержание AutoDyn
Страница 4: ...AutoDyn Operators Manual Section 1 Page 4 AutoDyn Cover fm...
Страница 5: ...1 General Information...
Страница 10: ...S Y S T E M O V E R V I E W Section 2 Page 1 2 System Overview...
Страница 24: ...P A C K A G I N G A N D H A N D L I N G Section 3 page 1 Packaging and Handling 3...
Страница 29: ...T E S T A R E A R E Q U I R E M E N T S Section 4 page 1 4 Test Area Requirements...
Страница 40: ...I N S T A L L A T I O N Section 5 Page 1 5 Installation...
Страница 55: ...6 System Operation...
Страница 60: ......
Страница 78: ...H A N D H E L D C O N T R O L L E R Section 7 Page 1 7 Handheld Controller...
Страница 104: ...8 Theory Of Testing...
Страница 114: ...Theory Of Testing Volume 2 9 10 04 Section 8 Page 13 Figure 8 1 Frontal Area Coefficient of Drag US...
Страница 115: ...AutoDyn Operators Manual Section 8 Page 14 Theory Of Testing fm Figure 8 2 Frontal Area Coefficient of Drag Metric...
Страница 123: ...9 Description of the Configuration File...
Страница 172: ...20 Service and Calibration...
Страница 178: ...S E R V I C E A N D C A L I B R A T I O N Section 20 page 7 20 2 Maintenance record...
Страница 193: ...A General Testing Information Appendix...
Страница 205: ...B Fundamental Concepts to Obtaining Superior Repeatability Appendix...