System Operation
Volume 1, 6/16/05
Section 6 - Page 13
13.
Select and Start the desired test via the handheld “Test” menu (Figure 6-8). Follow the
prompts to run the test. Data from the test will automatically be stored to the computer at
the end of the test. Repeat the test if desired.
Figure 6-8 Handheld Test menu
The test will prompt for the use of ProFilter. If used, there must be a good engine speed signal for
it to work properly. If ProFilter is used, the test will automatically set the correct parameters based
upon the chosen engine speed signal source. If a perfect engine speed signal is not possible,
ProFilter should not be used.
ProFilter is a special WinDyn feature that will take high speed recorded
data and post-process it to provide smoother data with even increments
of engine RPM on the data printout. See Chapter 3 in the WinDyn Users
Guide for more information on ProFilter and how to use it.
14.
Upon completion of the test, let the vehicle coast down to a stop and let it cool down as
necessary before shutting off the engine. The Eddy Current absorber will automatically
assist in stopping the vehicle. Wait for the roll to stop before getting out of the vehicle.
15.
Press “Shift F3” on the computer keyboard to open the saved data file dialog. Select the
desired file. Use the WinDyn Stored Data Viewer to analyze, print, and plot the data. See
Chapter 4 in the WinDyn Users Guide for more information on the Stored Data Viewer.
16.
Remove the vehicle from the dynamometer. See section 6.7 for details.
Push “Test” (the G button)
Push “Select Test” (the A button)
Push the number button corre-
sponding to the test.
Push “Start Test” (the B button)
Содержание AutoDyn
Страница 4: ...AutoDyn Operators Manual Section 1 Page 4 AutoDyn Cover fm...
Страница 5: ...1 General Information...
Страница 10: ...S Y S T E M O V E R V I E W Section 2 Page 1 2 System Overview...
Страница 24: ...P A C K A G I N G A N D H A N D L I N G Section 3 page 1 Packaging and Handling 3...
Страница 29: ...T E S T A R E A R E Q U I R E M E N T S Section 4 page 1 4 Test Area Requirements...
Страница 40: ...I N S T A L L A T I O N Section 5 Page 1 5 Installation...
Страница 55: ...6 System Operation...
Страница 60: ......
Страница 78: ...H A N D H E L D C O N T R O L L E R Section 7 Page 1 7 Handheld Controller...
Страница 104: ...8 Theory Of Testing...
Страница 114: ...Theory Of Testing Volume 2 9 10 04 Section 8 Page 13 Figure 8 1 Frontal Area Coefficient of Drag US...
Страница 115: ...AutoDyn Operators Manual Section 8 Page 14 Theory Of Testing fm Figure 8 2 Frontal Area Coefficient of Drag Metric...
Страница 123: ...9 Description of the Configuration File...
Страница 172: ...20 Service and Calibration...
Страница 178: ...S E R V I C E A N D C A L I B R A T I O N Section 20 page 7 20 2 Maintenance record...
Страница 193: ...A General Testing Information Appendix...
Страница 205: ...B Fundamental Concepts to Obtaining Superior Repeatability Appendix...