Supplemental Information
Appendix A - Page 206
AppA General Testing Information.fm
A.8
Cleaning Fuel Filters
SuperFlow’s high capacity fuel pump system also has high capacity filtration capabilities. The end
result is that regular cleaning of the fuel filter is necessary to insure consistent fuel delivery. Sure
signs of a clogged fuel filter are slow priming times for the pump and decreased fuel handling
capacity during operation. The fuel system’s filtration factor is determined by its 40 micron (0.0015
inch) capacity filter. This high capacity filter will trap grit, rust, flakes, lint, animal hair and insect
parts. If you are not testing with highly filtered fuel, your fuel system will have the primary
responsibility to catch the large quantity of contaminants you may not have realized were even
present.
To clean the system, remove the filter screen assembly from its canister and wash it using a parts
washing solvent. Never clean it with carburetor cleaner. After the filter has been cleaned, blow the
cleaning solution and any remaining particles off of the screen using an air hose. Hold the nozzle
of the hose at a 45 degree angle and blow air from the outside toward the inside of the filter
element.
Depending on the source of your fuel, regular cleaning schedules will vary. At the outset, we
recommend you clean the filter weekly.
A.9
Thermocouple Information
SuperFlow utilizes four kinds of type K thermocouples (yellow connector blocks, temperature
range from 0-1800 degrees F). Each one utilizes two wires to relay the temperature signal.
SuperFlow has recently switched to 0.125” thermocouples for the SF-902 systems. These provide
faster response times for improved data acquisition. Two types of 0.125" diameter thermocouples
in a 5" tube length feature either a closed or an open end. Twenty eight gauge wire (0.020"
diameter) is used in both. If the open end version is employed for measuring air temperatures, you
Table A-1: Thermocouple Specifications
Use
Diameter
Length
Wire gage
Time
Constant
Air, Exhaust
0.25",
6.35mm
5", 127mm
20#,
0.028"dia
< 0.3 sec
Fluids
0.25",
6.35mm
5", 127mm
20#,
0.028"dia
<10 sec
Air, Exhaust
0.125",
3.17mm
5", 127mm
28#,
0.020"dia
< 0.18 sec
Fluids
0.125",
3.17mm
5", 127mm
28#,
0.020"dia
< 4 sec
Содержание AutoDyn
Страница 4: ...AutoDyn Operators Manual Section 1 Page 4 AutoDyn Cover fm...
Страница 5: ...1 General Information...
Страница 10: ...S Y S T E M O V E R V I E W Section 2 Page 1 2 System Overview...
Страница 24: ...P A C K A G I N G A N D H A N D L I N G Section 3 page 1 Packaging and Handling 3...
Страница 29: ...T E S T A R E A R E Q U I R E M E N T S Section 4 page 1 4 Test Area Requirements...
Страница 40: ...I N S T A L L A T I O N Section 5 Page 1 5 Installation...
Страница 55: ...6 System Operation...
Страница 60: ......
Страница 78: ...H A N D H E L D C O N T R O L L E R Section 7 Page 1 7 Handheld Controller...
Страница 104: ...8 Theory Of Testing...
Страница 114: ...Theory Of Testing Volume 2 9 10 04 Section 8 Page 13 Figure 8 1 Frontal Area Coefficient of Drag US...
Страница 115: ...AutoDyn Operators Manual Section 8 Page 14 Theory Of Testing fm Figure 8 2 Frontal Area Coefficient of Drag Metric...
Страница 123: ...9 Description of the Configuration File...
Страница 172: ...20 Service and Calibration...
Страница 178: ...S E R V I C E A N D C A L I B R A T I O N Section 20 page 7 20 2 Maintenance record...
Страница 193: ...A General Testing Information Appendix...
Страница 205: ...B Fundamental Concepts to Obtaining Superior Repeatability Appendix...