Appendix D
Error Codes
D-5
60
NO LABEL. The bar code scanner
could not read the bar code label
because there was no label on the
cartridge.
If present, this error appears on the Label Info screen.
If the cartridge does not have a bar code label, place
a label on the cartridge. If there is a bar code label,
reposition or replace it. If the error persists, contact
your service provider.
61
READ ERROR. The bar code scanner
could not read the bar code label
because the label was unreadable.
62
NOT PRESENT. The bar code scanner
could not read the bar code labels
because there was no data cartridge
magazine present.
If present, this error appears on the Label Info screen.
If necessary, install a data cartridge magazine.
65
DMA OVERRUN. The bar code
scanner could not read the bar code
label because a Direct Memory Access
(DMA) overrun occurred.
If present, this error appears on the Label Info screen.
Make sure the tape library and the tape drives are
not being used by the host computer, then press
Reset on the operator panel. If this error still occurs,
contact your service provider.
67
DMA CH.2 TIMEOUT. Controller
board error.
69
LABEL UPSIDE DOWN. The bar code
scanner could not read the bar code
label because the label is upside down.
If present, this error appears on the Label Info screen.
Remove the label and reposition it on the cartridge.
If the label is affixed correctly, contact your service
provider.
70
L SERVO TIMEOUT. The CHM could
not reach its destination along the long
axis.
Open the door. Look for anything that might be
obstructing the CHM along its long axis.
Make sure the library and tape drives are not being
used by any host, then press Reset on the operator
panel. If the error persists, contact your service
provider.
71
PARAMETER > LIMIT. Firmware
error.
Make sure the tape library and the tape drives are
not being used by the host computer, then press
Reset on the operator panel. If the error still occurs,
contact your service provider. You may be asked to
supply a diagnostic listing, and you may need new
firmware.
TABLE D-1
Hardware Errors by Error Code (Continued)
Error
Number
Description
Corrective Action
Содержание StorEdge L400
Страница 24: ...xxiv Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 30: ...1 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 86: ...6 14 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 140: ...C 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 162: ...Index 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...