LARGE GABLE SHED

N3/C1 FRAME KIT

FOR HIGHLANDER MODELS

Model: CYCHK

02/03/21

1.2

1  

 

 

DOWNLOAD

 

OUR APP FOR

ASSEMBLY

VIDEOS

LEAVE A REVIEW

Tell us about your experience and 

receive a $20 Coles Gift Card.

Visit

 

www.abscosheds.com.au/review

AU: 1800 029 701

NZ: 0800 466 444

[email protected]

www.abscosheds.com.au

This kit is applicable to the following sheds:

The addition of this frame kit will increase the 
wind rating of the specified sheds to

Wind rating: N3/C1 as per AS4055-2012.
Suitable for specific cyclonic regions

60303HK
45232HK
30292HK

3060HK
3045HK

WARNING: This shed must be anchored to a 
100mm thick concrete slab with the concrete 
anchors supplied.
Failure to do so will result in the shed not 
having the structural integrity required to 
endure a severe storms or cyclonic event.

WARNING: Doors must remain closed with 
all padbolts properly secured during severe 
storms or cyclonic event.

View of frame kit applied to

3060HK

Where information conflicts with the original 
instruction manual, this document is to be 
referenced.

This instruction manual is to be used during 
the initial construction of the structure.

Содержание CYCHK

Страница 1: ...ds to Wind rating N3 C1 as per AS4055 2012 Suitable for specific cyclonic regions 60303HK 45232HK 30292HK 3060HK 3045HK WARNING This shed must be anchored to a 100mm thick concrete slab with the concrete anchors supplied Failure to do so will result in the shed not having the structural integrity required to endure a severe storms or cyclonic event WARNING Doors must remain closed with all padbolt...

Страница 2: ...g material supplied is 80 x 40 mm galvanised steel channel similar to that used in steel house framing Some channels are required to be cut to specific lengths using a hacksaw SITE PREPARATION The site for the shed must be level An uneven surface may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately If using a rebated sla...

Страница 3: ... Tab notch on both ends L 45mm Lip notch on one end only M 45mm Lip notch on both ends N 20mm Tab notch 45mm Lip notch P 20mm Tab notch 45mm Lip notch on both ends R One end 20mm Tab notch 45mm Lip notch S SPECIAL NOTCHING not noted above FRAME SECTION IDENTIFICATION GUIDE The first letter of the part number is used to identify the notching type EG K2940 see below for reference list The following ...

Страница 4: ...3 16 x 1 2 PAN HD BOLT FAST002 1 3mm POP RIVET 50 PACK FAST009 16 3 16 NYLOC NUT FAST003 3 45mm HEX TEK SCREW 26 PACK FAST019 3 HINGE 6 HOLE FAST012A 1 DOUBLE DOOR ANCHOR BRACKET BKT12 10 PADBOLT FAST006 4 CORNER BRACKET BKT10 4 PADBOLT HASP FAST007 38 MULTIPURPOSE BRACKET MPB BKT17 8 DOOR PLATE 4 CO 4 ZINC 12A 4 KNEE PLATE ZACO193 1 PHILLIPS HEAD DRIVER BIT FAST038 4 APEX PLATE ZACO194 1 3MM DRIL...

Страница 5: ...to centreline of portal frame Slab size specified in original manual 2 portal frame layout 45232WK NOTE One portal frame is supplied in original kit Positions of portal frames may differ from the original instruction manual For ease of assembly ALL portal frames shall be erected during the initial construction of the structure 1280 928 1675 715 1675 715 For 2 3m wide structures the following parts...

Страница 6: ...HK NOTE One portal frame is supplied in original kit FRAMING OVERVIEW Positions of portal frames may differ from the original instruction manual For ease of assembly front and portal frames shall be erected during initial construction of the structure Refer to next page for front frame specification 1773 1643 1430 1430 928 712 Dimension taken from edge of slab to centreline of portal frame Slab di...

Страница 7: ...supplied in original kit FRAMING OVERVIEW Positions of portal frames may differ from the original instruction manual For ease of assembly front and portal frames shall be erected during initial construction of the structure Refer to next page for front frame specification Dimension taken from edge of slab to centreline of portal frame Slab dimension specified in original manual 1470 ...

Страница 8: ...or battery drill for installation Do not attempt to fasten tek screws by hand If available make sure that the drill has the slow speed and high torque settings selected Fit the supplied driver bit into the chuck of the drill Place the tek screw onto the tip of the driver and place the tek screw into position using the weight of the drill to prevent it from moving Once in position apply a moderate ...

Страница 9: ... one side length of 38mm and another at 40mm 3 Slide opposing sides together so that each frame section fits neatly inside the other 5 Fix with tek screws Use tek screws to fix the two sections and complete a boxed frame member as shown Make sure that you alternate tek screw position on opposing sides of the boxed sections Align tek screws 296mm apart This is approximately 2 sheet corrugations in ...

Страница 10: ...gether and fix with tek screws C2300 C2300 x1 C0240 C0240 x1 C2034 N2070 x2 Additional framing is supplied in this frame kit K0285 x6 and C2034 x2 All other frame parts are supplied in the original shed kit NOTE These frames will need to be trimmed by 25mm to suit a rebated slab HIGH FRONT FRAME ASSEMBLY N3 C1 C2034 C0100 C2034 N2070 C2300 M1484 ZACO190 ZACO9A C0240 BKT17 K0285 BKT17 Applies to 30...

Страница 11: ...e slab Secure the small triangular plate ZACO190 to the exterior side of the frame Secure the ridge plate ZACO9A to the interior side of the frame 325 325 2300 2000 100 870 193 193 193 315 315 315 2295 40mm all sections Layout all sections as shown in the same manner as a portal frame Use 16mm self drilling screws to join all components together with three screws at all connecting points on both s...

Страница 12: ...ODELS Model CYCHK 02 03 21 1 2 12 ANCHORING LAYOUT Slab dimensions below illustrate the minimum required anchors per wall Ensure that anchors are evenly spaced along wall 5323mm for 5 2m wall 6060mm for 6 0m wall 3100mm for 3 0m wall 4580mm for 4 5m wall 2360mm for 2 3m wall 3020mm for 2 9m wall ...

Страница 13: ... masonry bit Holes must have a minimum slab edge distance of 60mm Bolt and nut through the wall sheet requires the drilling of a 10mm hole through the wall sheet Portal frame anchoring detail shown in section PORTAL FRAME DETAIL Inside view of typical anchor Outside view of typical anchor Door stud Not portal frame have a single anchor through a BKT17 Fixed by four tek screws Double door openings ...

Страница 14: ...g screw Pre drill and reinforce with extra screws at 148mm centres in the following locations B Roof panel to wall C Roof panel to ridge beam inside G Wall sheet to wall channel inside Pre drill and reinforce with extra screws at 296mm centres in the following locations A All sheet to sheet connections D Wall corners E Roof lip to sheet F Sheet to channel 3060HK shown for illustrative purposes D D...

Страница 15: ...oof panel at 148mm centres every pan then fix with a screw Some screws will already be in these positions skip these G Wall sheet to top wall channel Pre drill from inside the shed through the top channel and into the wall sheet at 148mm centres every pan and then fix with a screw Do this on the non gable walls only For illustrative purposes fasteners are shown on just one side of the ridge beam R...

Страница 16: ...face and use one tek screw at each join NOTE If the door has been completely assembled as per original instruction manual you will need to remove the diagonal door braces 3 Make sure the frame is square and fix with a second tek screw at each join 4 Turn frame over and repeat last step 1 Seal any brace holes using the supplied pop rivets FAST007 Perform from the outside of the door K0640 C1555 ...

Страница 17: ...t FAST005 4x bolt FAST004 NOTE Fit to exterior for double doors Horizontal position D 1x Padbolt FAST006 1x Door plate 12A 1x Hasp FAST007 6x Self tapping screws FAST001 10 Drill 10mm holes in the jamb above the door ref image B and the channel below the door ref image C These align with the vertical padbolt shafts of double doors DOOR BRACING 6 Use tek screws to fix the frame to the door at every...

Страница 18: ...lly box them together do not tek screw yet 2 Place the unscrewed box section against the wall in the orientation pictured and slide the two pieces apart until they make contact with the wall and the portal frame This will also be the case between portal frames The result should look similar to what is pictured to the right Gable wall 80mm N on gable wall Bracing installed on the non gable wall bet...

Страница 19: ...asten all boxed frame sections to the non gable wall from the outside of the shed This task is best done with two people Secure the wall bracing to the portal frame using a BKT17 and tek screws on either side as shown For the open side of the portal frame take a piece of offcut approx 150mm long and box as shown NOTE This method will be used later to mount the roof bracing ...

Страница 20: ...e floor and the roof panel 2 Once the correct lengths have been determined proceed to fix them with tek screws at 296mm spacings as described in BOXING FRAME SECTIONS 3 Fix wall bracing to this stud with BKT17 as previously shown in BRACING FOR NON GABLE WALLS PORTAL FRAME 4 Fix roof panel to the top of the stud using BKT 17 as shown below In instances where a portal frame is not positioned on bot...

Страница 21: ...This is shown below 3 Now the framing is at the correct length proceed to fix them together as per method described in BOXING FRAME SECTIONS 4 Now boxed use tek screws to fix it to the gable wall from the outside of the shed This is best done with two people Gable wall Gable wall N on gable wall Previously installed wall bracing on the left and new gable wall bracing on the right 5 Use corner brac...

Страница 22: ...reline of the bracing Proceed to drill a hole in every 2nd flat section of the roof sheet 3 Where the bracing meets the open side of the portal frame it will need to be boxed as before in section BRACING FOR NON GABLE WALLS PORTAL FRAME 4 While one person holds the roof brace in position use tek screws to fix the framing from the outside of the shed IMPORTANT Do not sit stand or walk on the roof o...

Страница 23: ...rrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other products which are...

Страница 24: ...s of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin absco com au You will be required to produce proof of purchase this is at discretion of the manufacturer at the time of the claim The manufacturer bears the cost of replacing the products or spare p...

Страница 25: ... equipment and should not be used for articles that may be prone to damage if they come into contact with moisture 3 Major Defects If the manufacturer is satisfied that the defect is a major defect the purchase price may be refunded in lieu of providing a replacement product or repairing the product This warranty is provided in addition to other rights and remedies you have under law Our goods come...