Appendix D
Error Codes
D-13
D.2.4
Unit Attention—Sense Key 6h
The tape library does not stack Unit Attention conditions. The tape library reports
only the last Unit Attention condition when there are two or more Unit Attention
conditions. A Unit Attention condition remains in effect for a particular initiator
until that initiator clears it.
TABLE D-6
lists combinations of ASC and ASCQ values for the Unit Attention sense
key (6h).
80h
03h
The source cartridge magazine is not installed.
80h
04h
The destination cartridge magazine is not installed.
80h
05h
The source tape drive is not installed.
80h
06h
The destination tape drive is not installed.
85h
01h
The bar code scanner is not installed.
TABLE D-6
Unit Attention Sense Key (6h) ASC and ASCQ Values
ASC
Byte 12
ASCQ
Byte 13
Description
28h
00h
The door was opened then closed.
28h
89h
The tape library was placed in SCSI Interface mode after operating in
one of the serial port modes.
28h
8Dh
The tape library was placed in SCSI Interface mode after operating in
LCD mode.
28h
8Eh
The tape library was placed in SCSI Interface mode after operating in
one of the sequential modes (Sequential CTS1, Sequential CTS2, or Dual
Sequential).
29h
00h
A power-on, SCSI bus reset, or device reset message occurred.
2Ah
01h
Mode parameters have been changed. Issue a MODE SENSE (1Ah)
command to determine what the new mode parameters are.
3Fh
01h
New microcode was loaded.
TABLE D-5
Illegal Request Sense Key (5h) ASC and ASCQ Values (Continued)
ASC
Byte 12
ASCQ
Byte 13
Description
Содержание StorEdge L400
Страница 24: ...xxiv Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 30: ...1 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 86: ...6 14 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 140: ...C 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...
Страница 162: ...Index 6 Sun StorEdge L400 Installation and User s Guide April 1998 ...