Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
542
8
SlavScal
P64 Skal.-Fkt.
8
The resulting standardized reference position of the slave from the
cam table is multiplied by the value on
SlavScal
and divided by the
standardization value 2
30
.
9
SlavOffs
I32
–
The slave offset is added to the scaled output value of the cam table.
10
StepID
U16
–
Motion job ID
Outputs
No. Name
Datatype Scaling
Description
11
InCam
B –
Status
signal;
1:active
= the command was executed successfully.
12
Aborted
B –
Status
signal;
1: active
= motion job was aborted by another job.
13
Error
B –
Status
signal;
1: active
= position control found an error.
14
ErrorID
U16 –
Indication of the error code as per
I90
(due to error found by position
control)
15
Active
B –
Status signal;
1: active
= block sends the motion job to position
control or executes it.