Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
547
100984 Set values for fast electronic master cam 2
Description
The block supplies reference values for electrical master cam 2 with a cycle time of 1 ms. It
provides the parameter
N112
for the cam start position and
N113
for the cam end position.
The value 1 is permanently output to the output
Mstr/Slv
. This output can be directly
connected to the applicable input of the cam block. The start position is output to the output
CamStart
and the end position of the cam to the output
CamEnd
.
NOTE
Remember that this block may only be used in the electronic cam application.
Outputs
No. Name
Datatype Scaling
Description
1
Mstr/Slv
U8 –
0: Slave cam
1: Axis cam
2
CamStart
P64
Skal.-Fkt. 19
Start position of the cam
3
CamEnd
P64
Skal.-Fkt. 19
End position of the cam