Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
335
100013 X102.AE3
Description
The block writes the current value of the analog input to the display parameter
E74
AE3-Level. The
value is added to
F31
AE3-Offset and multiplied by
F32
AE3 Gain. The result is output to
Out
.
(AE3-Level +
F31
) x
F32
=
Out
Outputs
No. Name
Datatype Scaling
Description
1
Out
I16 16384=10V
Level of the analog input AE3 calculated with
F31
AE3-Offset and
F32
AE3 Gain (terminal X102.1-X102.2)