System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
170
174 Controlled negate R32
Description
The block executes a controlled negation. When signal 0 is written to the input
Ctrl
, the value
on
In
is output unchanged to
Out
. When
Ctrl
contains signal 1, the value on
In
is negated and
written to
Out
.
Inputs
No. Name
Datatype Scaling
Description
1
In
R32 –
Input
value
2
Ctrl
B –
Control input:
0 = Input value on
In
is output unchanged to
Out.
1 = Input value is negated and output to
Out
.
Outputs
No. Name
Datatype Scaling
Description
3
Out
R32 –
Output
value