System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
65
36 Addition with saturation I16
Description
The block calculates the sum of input variables
In1
and
In2
. Computation is limited to the value
range of the data format. The block checks to determine whether the result is within these
limits. If this is not the case, the exceeded limit value is written as the result.
Inputs
No. Name
Datatype Scaling
Description
1
In1
I16 –
First
summand
2
In2
I16 –
Second
summand
Outputs
No. Name
Datatype Scaling
Description
3
Out
I16
–
Result of the addition (limited to value range of I16)