Notes on Safety
Block descriptions
ID 441692.01
www.stoeber.de
5
STÖBER ANTRIEBSTECHNIK
Proceed as shown below to perform these tasks:
1. Disable the enable (X1).
2. Turn off the supply voltage (power pack and controller power supply
as well as any auxiliary voltages for encoder, brake, etc.).
3. Protect the supply voltages from being turned on again.
4. Wait 5 minutes (time the DC link capacitors need to discharge)
5. Determine isolation from the voltage.
6. Short circuit the network input and ground it.
7. Cover the adjacent, voltage-carrying parts.
You can then start your work on the drive controller.
Repairs may only be performed by STÖBER ANTRIEBSTECHNIK GmbH +
Co. KG. Send defective devices together with a fault description to:
STÖBER ANTRIEBSTECHNIK GmbH + Co. KG
Abteilung VS-EL
Kieselbronner Str.12
75177 Pforzheim
GERMANY
Disposal
Please comply with the latest national and regional regulations!
Dispose of the individual parts separately depending on their nature and
currently valid regulations such as, for example
•
Electronic scrap (PCBs)
•
Plastic
•
Sheet metal
•
Copper
•
Aluminum
Residual dangers
The connected motor can be damaged with certain settings of drive controllers:
•
Longer operation against an applied motor halting brake
•
Longer operation of self-cooled motors at slow speeds
Drives can reach dangerous excess speeds (e.g., setting of high output
frequencies for motors and motor settings which are unsuitable for this).
Secure the drive accordingly.
Содержание POSIDRIVE MDS 5000
Страница 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Страница 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Страница 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Страница 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Страница 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...