Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
424
100444 Command Positioning PLCopen (input block)
Description
The block generates the control signals for command positioning from the analog inputs,
binary inputs or from fieldbus process data. It is used with block 100265, for instance.
Outputs
No. Name
Datatype Scaling
Description
1
/HW-Lim+
B –
The output supplies the state of the source which was specified by the
parameter
I101
/HW-Limit- source (binary input or
I222
, bit 1).
Command positioning uses the output to indicate the state of the
positive HW limit switch.
2
/HW-Lim-
B –
The output supplies the state of the source which was specified by the
parameter
I102
/HW-Limit-Switch- source (binary input or
I222
, bit 2).
Command positioning uses the output to indicate the state of the
negative HW limit switch.
3
TipEnabl
B –
The output supplies the state of the source which was specified by the
parameter
I104
Tip enable source (binary input or
I222
, bit 4).
Command positioning uses the signal to activate tipping mode.
4
Tip+
B –
The output supplies the state of the source which was specified by the
parameter
I105
Tip+ source (binary input or
I222
, bit 5).
Command positioning uses the signal to travel in tipping mode in the
positive direction.
5
Tip-
B –
The output supplies the state of the source which was specified by the
parameter
I106
Tip- source (binary input or
I222
, bit 6).
Command positioning uses the signal to travel in tipping mode in the
negative direction.
6
B –
The output supplies the state of the source which was specified by the
parameter
I107
H source (binary input or
I222
, bit 7).
Command positioning uses the signal to step in tipping mode in the
positive direction.
7
TipStep-
B –
The output supplies the state of the source which was specified by the
parameter
I108
HandStep- source (binary input or
I222
, bit 8).
Command positioning uses the signal to step in tipping mode in the
negative direction.
8
RefSwitc
B –
The output supplies the state of the source which was specified by the
parameter
I103
reference switch source (binary input or
I222
, bit 3).
Command positioning uses the output to supply the reference switch
signal.
Содержание POSIDRIVE MDS 5000
Страница 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Страница 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Страница 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Страница 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Страница 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...