Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
440
100797 Fast electronic cam 3 lim. pos. range
Description
The block contains the function of a fast cam for the limited position range. The block is
calculated with a cycle time of 1 ms.
The actual position of the slave drive must be connected to the input
XActSlvL
and the related
timestamp must be connected to the input
Slave TS
.
The signal on the input
Mstr/Slv
specifies whether the cam is a slave cam or a master cam.
The start and end positions of the cam are connected to the inputs
CamStart
and
CamEnd
.
The cam is calculated when the signal of the input
CamEnabl
is active. The cam is disabled when
the signal is inactive.
The output signal of the cam is written to the display parameter
N80
.2. Remember that the
parameter is updated with the regular technology cycle time
A150
.
Inputs
No. Name
Datatype Scaling
Description
1
XActSlvL
P64
Skal.-Fkt. 8
Actual position of the slave in the limited position range
2
Slave TS
U16
1LSB = 1us
Timestamp of the signal on the input
XActSlvL
3
Mstr/Slv
U8 –
0: Slave cam
1: Master cam
4
CamStart
P64
Skal.-Fktn. 8 / 19
Start position of the cam. This value applies to the master or the slave
depending on the type of cam.
5
CamEnd
P64
Skal.-Fktn. 8 / 19
End position of the cam. This value applies to the master or the slave
depending on the type of cam.
6
CamEnabl
B –
0: The cam is not calculated.
1: The cam is calculated.
Содержание POSIDRIVE MDS 5000
Страница 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Страница 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Страница 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Страница 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Страница 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...