System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
287
411 range monitor
Description
The block monitors whether the value on
In
is within the range defined by
LimL
and
LimU
.
The input
Absolute
provides an absolute value on the input. Monitoring can be switched
off via
Enable
.
Inputs
No. Name
Datatype Scaling
Description
1
Input
I16
–
Value to be monitored
2
LimU
I16
–
Upper limit value of the range
3
LimL
I16
–
Lower limit value of the range
4
En
B –
0:
Out
=0 (no range monitoring)
1: Range monitoring active
5
Absolute
I8 –
0: Range monitoring of the unchanged signal
In
1: Range monitoring of the absolute value of the signal
In
Outputs
No. Name
Datatype Scaling
Description
6
Out
U8 –
0:
LimL
≤
In
≤
LimU
or
LimL
≤
|
In
|
≤
LimU
or
Enable
=
0:inactive
1:
In < LimL
or |
In
| <
LimL
2: LimU < In or LimU < |In|
Содержание POSIDRIVE MDS 5000