Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
437
100794 Set values for fast electronic axis-cam 1
Description
The block supplies the reference values for electrical axis cam 1 with a 1-ms cycle time. It
provides the parameters
N104
for the cam's starting position and
N105
for the cam's end
position. The value 0 is permanently output to the output
Mstr/Slv
. This output can be
directly connected to the applicable input of the cam block. The start position is output to
the output
CamStart
and the end position of the cam is output to the output
CamEnd
.
NOTE
Remember that this block may only be used in the electronic cam application.
Outputs
No. Name
Datatype Scaling
Description
1
Mstr/Slv
U8 –
Constant value: 0. A slave cam is set with this value for connection to
block 100795, for example.
2
CamStart
P64
Skal.-Fkt. 8
Start position of the cam
3
CamEnd
P64
Skal.-Fkt. 8
End position of the cam