Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
576
101145 Digital inputs 2
Description
The block generates control signals from the binary inputs or from control word
D210
for the
comfort reference value application.
Binary inputs BE1 to BE8 are imaged in parameter
F200
.
NOTE
The block is used automatically in the configuration of the axis if you generate the comfort
reference value application.
Outputs
No. Name
Datatype Scaling
Description
1
Reverse
B
The output supplies the state of the source which was specified by the
parameter
D100
reverse source (binary input or
D210
bit 0).
The signal can be parameterized with a switchon or switchoff delay with
the parameters
D400
.x. The comfort reference value application uses
the signal to change the direction of rotation.
2
ExtFault
B
The output supplies the state of the source which was specified by the
parameter
D101
external fault source (binary input or
D210
bit 1).
The signal can be parameterized with a switchon or switchoff delay with
the parameters
D401
.x. The comfort reference value application uses
the signal to trigger a fault externally.
3
Stop
B
The output supplies the state of the source which was specified by the
parameter
D102
stop source (binary input or
D210
bit 2).
The signal can be parameterized with a switchon or switchoff delay with
the parameters
D402
.x. The comfort reference value application uses
the signal to trigger a stop.
4
LimSwiP
B
The output supplies the inverted state of the source which was specified
by the parameter
D103
limit source (binary input or
D210
bit 3).
The signal can be parameterized with a switchon or switchoff delay with
the parameters
D403
.x. The comfort reference value application uses
the signal to indicate the inverted state of the positive limit switch.
5
LimSwiN
B
The output supplies the inverted state of the source which was specified
by the parameter
D104
limit switch- source (binary input or
D210
bit 4).
The signal can be parameterized with a switchon or switchoff delay with
the parameters
D404
.x. The comfort reference value application uses
the signal to indicate the inverted state of the negative limit switch.
Содержание POSIDRIVE MDS 5000
Страница 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Страница 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Страница 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Страница 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Страница 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...